The XL-3528SRIRC is a 3528 blood oxygen emitting patch LED. Its size is 3.5 × 2.8 × 1.9 mm, with a transparent epoxy package that houses both red and infrared emission chips (the datasheet provides optical parameters for red light 650/660 nm and infrared 940/950 nm). It's suitable for scenarios like blood oxygen monitoring where red and infrared emission is needed. The product meets ROHS environmental standards, has a moisture sensitivity level (MSL) of 3, uses EIA standard packaging, and is compatible with SMT automated production and infrared reflow soldering processes.

Package and Process: 3528 package, 4 pins, size 3.5×2.8×1.9 mm, transparent epoxy, MSL level 3, RoHS compliant, supports SMT mounting and IR reflow soldering.
Optoelectronic Parameters (IF=20mA):
Wavelength: Red 650/660 nm; Infrared 940/950 nm; FWHM 35 nm.
Forward Voltage VF: 1.4–1.9 V.
Radiant Intensity Ie: 2/5 mW (grading P1-1: 0.5–3 mW/Sr; P1-2: 3–5 mW/Sr).
Luminous Flux/Luminous Intensity: 200/400 mcd.
Viewing Angle: 120°.
Reverse Current IR: ≤10 μA (VR=5V).
Binning Information:
Radiant Intensity: P1-1 (0.5–3 mW/Sr), P1-2 (3–5 mW/Sr).
Voltage: N17-5 to N17-8, covering 1.4–1.9 V.
Wavelength: HR06 (640–645 nm), HR07 (645–650 nm), IR02 (930–940 nm), IR03 (940–950 nm).
Absolute Maximum Ratings:
Power Dissipation Pd: 75 mW
Max Continuous Forward Current IF: 20×2 mA
Forward Pulse Current IFP: 80×2 mA (pulse width ≤0.1ms, duty cycle ≤1/10)
Reverse Voltage VR: 5 V
Operating/Storage Temperature: -40 to 85℃
Reflow Soldering Temperature: 260℃/6s
Usage Notes: A current-limiting resistor is required to prevent overcurrent due to slight voltage changes; avoid applying mechanical pressure or scratching the epoxy.
Medical devices (like blood oxygen monitors)
Infrared remote controls
Surveillance cameras
Industrial control: counters, thermal imaging, smart meters
Infrared photoelectric switches
Wireless communication and signal transmission
Smart cars, robots